We are engaged in supplying of current and voltage transformers like distribution transformer, control voltage transformer, LT current transformer, air-cooled transformer, etc., of indoor & outdoor type that are extensively used in electricity boards and for commercial supply. Good quality of raw materials is used in the production of these transformers that is procured from genuine vendors. It is highly appreciated for its efficiency and performance. Our wide range includes:
Products:
Voltage Transformer
Control Voltage Transformer
Current Transformer
LT Current Transformer
Air Cooled Transformer
Voltage Transformer
We are engaged in supplying voltage transformer that is used for the metering and protection purposes. We also offer three phase residual voltage transformers with the standards value of secondary voltage in PT that amounts to 110 V or 110/3 and the value of rate burden is 10A to 500A at t power factor of 0.8 lagging. The standards accuracy of class for measuring PT is:
0.1
0.2
0.5
1.0
3
The standard accuracy of class for protective PT is 3P and 6P, the standard accuracy of class for three-phase residual voltage transformer is:
5PR
6PR
It is supplied in accordance with necessary standards and can be easily modified as per client requirement.
Control Voltage Transformer
We offer air-cooled control voltage transformer that is manufactured using advanced machinery. The machinery includes dust proof winding, toroidal core winding machine, vacuum plant and many more. It is extensively use in electrical and industrial areas. It can be easily customized as per client specification and can be delivered within stipulated time frame. Some of its noteworthy features include:
Power saving (reduction in power bill)
Reduction in breakdown of electrical equipment
Better efficiency
Current Transformer
We offer current transformer that is high highly appreciated for its longevity and current feedings. This type of transformers is used for metering and special protection purposes. 1A or 5A is the standards value of the secondary current in this transformer. The standard value of the rated burden is up to 30VA that includes:
2.5VA
5VA
7.5VA
10VA
15VA
30VA
Accuracy of the class in metering of current transformers is 0.1 , 0.2 , 0.2S , 0.5 , 0.5S , T.0 or 3 and the standards accuracy class in protection of current transformer is 5P, 10P or 15P and the accuracy limit factor 5, 10, or 15. The special purpose of current transformer applications is balanced protective system and distance protective schemes. The application of this transformer is based on distance protective schemes and balanced protective system. The necessity of PS class are rated maximum voltage current and knee point voltage and the resistance of secondary winding at 75o C. it is manufactured in compliance with required standards and can be delivered within given time frame.
LT Current Transformer
We supply LT current transformer that is known for its effective functioning among our valued clients and is extensively used for ind